Maxtronic Sivy SA-3830
Arena is eight bay Serial ATA tower. Featuring the Intel i80321 64-bit RISC microprocessor and transfer speeds up to 320MB/s. The SA-3830 is the solution for small and midsize businesses.
The Sivy SA-3830 is a single controller, Ultra320 SCSI to SATA-I RAID system. In a compact tower, featuring hot-swappable power supplies and fans. The fans, and power supplies are modularized allowing for easy removal from the rear of the unit.
Особенности
Disk Self Test (DST)
Before the release of this function, users of RAID systems were forced to test suspected bad hard drives in a host computer individually using a drive manufacturer utility. This function tests the health of hard drives with them installed in the RAID unit. DST performs write tests, servo analysis, and read scan tests; the test results are then displayed on the LCD and hyper terminal output. This can aid the user in deciding whether or not to replace a suspected failing hard drive. We highly recommend running this test before initializing a RAID set to ensure a healthy RAID solution.
Disk Scrubbing (DS)
With today’s RAID subsystems being capable of storing multiple terabytes, it is becoming increasingly difficult to manage and maintain that large amount of data. To aid a user in maintaining their data’s health, Arena-MaxTronic has released their newest firmware function Disk Scrubbing. The data and/or parity stored on hard drives can sometimes become corrupted; this data can also reside in areas that are not accessed for long periods of time. DS will use idle time to test the disks, and if a sector is found to be corrupted, the data will be regenerated from other RAID member disks and will be written to an uncorrupted sector. The purpose of DS is to prevent the possibility of having multiple corrupted sectors in a single stripe, which is one of the main causes of data loss.
Disk Clone (DC)
Hard drives are the most likely component to fail in a RAID array, and almost impossible to predict when the failure will occur. When a failure does occur the RAID unit will have to regenerate data from the non-failed hard drives to rebuild a new drive, and the RAID array will be in degraded mode. Having a unit in degraded mode is a very cautious time because if a second hard drive was to fail the RAID is destroyed and data is lost. This is where Disk Cloning can aide a user. With the help of the hard drives built in S.M.A.R.T. function, DC can determine when to begin cloning a bad drive to a hot spare. Upon completion of cloning, the new cloned disk can take the position of the failing disk or can stand-by until the original disk fails, then take the failed disks position. Disk cloning is to prevent a rebuild from ever occurring and having the unit in degraded mode.
Support for greater than 2TB slice and LUN
Two firmware options are available to surpass the 2 terabyte limitation; 16byte CDB and variable sector size. With either of these functions enabled, users are able to create slices and map LUNs greater than 2TB to their respective host channels. See support documentation for compatibility or contact technical support for more information.
Online Initialization
Initialization occurs during creation of a RAID array by zeroing out / formatting drives. By default the initialization process occurs with the unit offline, and inaccessible. With online initialization, the RAID array can be accessed during the initialization process so that the unit can be setup without having to wait several hours to complete initialization. - BBU An optional BBU can be included in the RAID system to ensure data integrity in the event of a power outage. The BBU, or battery backup unit, will provide power to the on-board cache of the RAID controller in the event of a power outage. This will allow any data that is still stored on the cache to be saved until power is restored. Once power is restored, the RAID controller will flush the cache to drives.
Технические характеристики |
|
Host Interface | Ultra 320 SCSI |
Data Transfer Rate | Up to 320 MB/second per channel |
ID Assignment | 0-15 |
Number of Host Channels | 2 |
External Connector Type | HPD x 4 (68 pin High Density) |
Expansion | SCSI Daisy Chain |
Controller | CPU Intel i80321 RISC CPU (600 Mhz) |
Cache Memory | 512MB - Upgradable to 1GB DDR 333 SDRAM (PC2700 200-pin SODIMM ) |
Disk Interface | SATA-I (1.5 Gb/sec) |
Number of Disk Channels | 8 |
Hot Swap Disk Tray | 8 x 3.5" hot-swappable trays |
Hot Swap Fan | 2x 3600RPM Turbo Fan |
Hot Swap Power supplies | 460watt x 2 Redundant |
AC Input Voltage | 100 to 240V (+/- 10%), 46 to 63 Hz |
RAID Levels | JBOD, 0, 1, 0+1, 3, 5, 30, 50, NRAID |
RAID Arrays | 8 |
Data Rebuild | Automatic Data Regeneration |
RAID Features | Global Hotspare, Multiple Host ID, Multiple RAID Arrays and Multiple Slices, and Background Initialization |
Advanced Data Reliability | Assurance SMARTCor. Functions (DST, DS, DC) |
Online Expansion | Yes |
Front Panel | LCD and Buttons Easy access for configuration and status report. |
RS-232 | Terminal User Friendly interface for configuration and status report |
GUI | Global-net standalone management software |
Event Notification | Built-in buzzer, e-mail, and SNMP |
Humidity | 10% to 85% non-condensing |
Operating Temp | 5 C to 40 C |
Non-Operating Temp | -25 C to 60 C |
Safety Regulatory | UL, CUL, CB |
EMC Standard | FCC, CE, C-Tick, BSMI |
Physical Dimensions | 200 (W) x 321 (D) x 336 (H) mm |
Physical Weight | 11.5 Kgs (without drives) |