The more throughput that goes through a server, the more expensive its downtime. The Sun Fire V445 server is by far the best performer in its class, and the only one in its class capable of offering an average unplanned downtime of just three minutes per year. The extreme reliability of the Solaris OS on UltraSPARC systems provides a great base to grow your business. When you can pack up to four UltraSPARC IIIi processors and new high-speed I/O into the package, you"ll be even more impressed by the Sun Fire V445 server"s performance.
Architecture
|
|
---|---|
Processor | Two to four UltraSPARC IIIi 1.6 GHz |
Architecture | 64-bit, 4-way superscalar SPARC V9 |
Cache | 64 KB data, 32 KB instruction and 1 MB integrated L2 |
Memory
|
|
Main Memory | 4 DIMM slots per processor, DDR-1 SDRAM system configurations from 4 GB to 32 GB |
Standard/Integrated Interfaces
|
|
Network | Four 10/100/1000Base-T Ethernet |
Network Management | One 10Base-T Ethernet |
Serial Management | One TIA/EIA-232-F (RJ45) port |
Serial | One TIA/EIA-232-F asynchronous (DB9) port |
USB | Four USB 2.0 compliant ports, two front and two rear |
Expansion Bus | Eight internal slots Four PCIe (two long and two short, all full-height) Four PCI-X (two long and two short, all full-height) |
Mass Storage and Media
|
|
Internal Disk | Up to eight hot-plug 10,000-rpm SAS 73 GB disks, 146 GB optional |
Internal DVD | One Slimline ATAPI combination CD/DVD-RW |
External Disk |
|
External Tape |
|
Software
|
|
Operating System | Solaris 10 OS beginning with 06/06 Solaris 9 OS beginning with 09/05 HW |
Sun Java Enterprise System | Sun Java Enterprise System 2004Q2 available on select configurations only (90 day evaluation version) |
Languages | C/C++, FORTRAN, Sun Java programming language; all other standard Sun-supported languages |
Networking | ONCTM, NFS, TCP/IP, SunLink, OSI, MHS, IPXTM/SPX |
Management | Sun Management Center, Sun SNMP Management Agent, Advanced Lights Out Management (ALOM), Sun Net Connect and Sun Update Connection |
Power Supplies
|
|
Redundancy | Two required, four for redundancy |
Maximum AC Power | 788 W, 2689 BTUs/Hr |
Typical AC Power | 557 W, 1901 BTUs/Hr |
Environment
|
|
AC power | 100 - 240 V AC (50 - 60 GHz) |
Operating Temperature | 5° C to 35° C (41° F to 95°), 20% to 80% relative humidity, non-condensing, 27° C max. wet bulb |
Non-operating Temperature | -40° C to 60° C (-40° F to 140°), up to 93% relative humidity, non-condensing, 38° C max. wet bulb |
Operating Altitude | Up to 3,000 m, maximum ambient temperature is derated by 1° C per 500 m above 500 m |
Non-operating Altitude | Up to 12,000 m |
Acoustic Noise | 6.7 Bels operating and 6.7 Bels idle |
Regulations
|
|
Product Safety | UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all country deviations, IEC825-1, 2, CFR21 part 1040, CNS14336 |
RFI/EMC | EN55022 Class A, 47 CFR 15B Class A, ICES Class A, VCCI Class A, AS/NZ 3548 Class A, CNS 13438 Class A, KSC 5858 Class A, GB 9254 Class A, EN61000-3-2, GB 17625.1, EN61000-3-3 |
EMI | 47 CFR 15B (Code of Federal Regulations,Part 15, Subpart B) Class A; EN55022 Class A per EMC Directive 89/336/EEC (CE Mark); VCCI Class B; Industry Canada ICES-003; AS/NZ 3548 (Australia/New Zealand); CNS 13438 (Taiwan); KSC 5858 (MIC Mark/Korea) |
Immunity | EN55024/CISPR24 |
Telecommunications | EN300-386 |
Regulartory Marking | CE, FCC, ICES-003, C-tick, VCCI, GOST-R, BSMI, MIC, UL/cUL, UL/S-mark |
RoHS | Restriction of Hazardous Substances (RoHS) directive 2002/95/EC Labeled per Waste Electrical and Electronic Equipment (WEEE) Directive |
Immunity Certifications
|
|
IEC 1000 | EN55024 per EMC Directive 89/336/EEC, including IEC 61000- 4-2 Electrostatic discharge immunity test IEC 61000-4-3 Radiated, radiofrequency, electromagnetic field immunity test IEC 61000-4-4 Electrical fast transient/burst immunity test IEC 61000-4-5 Surge immunity test IEC 61000-4-6 Immunity to conducted disturbances, induced by radio-frequency fields IEC 61000-4-8 Power frequency magnetic field immunity test IEC 61000-4-11 Voltage dips, short interruptions and voltage variations immunity tests |
Line Distortion | EN 61000-3-2 per EMC Directive 89/336/EEC |
Voltage Fluctuations and Flicker | EN 61000-3-3 per EMC Directive 89/336/EEC |
Dimensions and Weight
|
|
Height | 174.5 mm (6.87 inches) |
Width | 445 mm (17.5 inches) |
Depth | 644 mm (25.4 inches) |
Weight | 37 kg (82 lb.) fully configured |
Enclosure | Fits into a standard 19-inch wide rack-mount kit that complies with EIA-310-D1992 standard |
Upgrades
|
|
Available Upgrades | Upgrades are available for SPARC server and Sun Enterprise systems. Contact your local Sun sales representative for details |
Warranty
|
|
Hardware support | 1 year |
Software install | 90 days |
Call response | 8 hours |
Delivery | Second business day, on-site |