Architecture
|
Blade Options |
- Netra CP3060 UltraSPARC ATCA
- Netra CP3010 UltraSPARC
- Netra CP3020 Opteron
|
|
Processor Options |
Choice of:
- One or two UltraSPARC IIIi at 1.1 GHz
- AMD Opteron processor, single-core: 2.2 GHz
- AMD Opteron processor, dual-core: 1.8 GHz
|
System Specifications
|
Main Memory |
Up to eight GB using DDR-1 technology |
|
Cache |
UltraSPARC: One MB AMD Opteron processor: One MB |
|
Disk Controller |
LSI 1064: SAS controller |
|
Operating System Support |
- Netra CT900 with CP3010 SPARC Blade: Solaris 9 OS or Solaris 10 OS
- Netra CT900 with CP3020 Opteron Blade: Solaris 10 OS, MontaVista Linux, Red Hat Linux, or Windows 2003
|
|
Rackmount Kits |
19-inch 600mm ETSI |
|
Network |
Standard interfaces Dual 10/100/1000Base-T Ethernet ports |
|
System Management |
Two system management cards: Redundant IPMI management |
|
I/O Interfaces |
Front and rear panel I/O |
|
Front Panel |
- Dual serial ports using RJ45 connectors with Netra (Cisco) pinout on SPARC®-based version, single serial ports on AMD Opteron processor-based version
- Dual RJ45 jacks for 10/100Base-T Ethernet for maintenance
- Dual PMC I/O access on the front panel, specific I/O dependent on PMC cards used
- Dual SAS ports (SPARC-based version only)
- Recessed reset switch
- One DB15 for telecom alarm relays
|
|
Rear Transition Module |
- Dual serial ports using RJ45 connectors with Netra (Cisco) pinout
- Dual RJ45 jacks for 10/100Base-T Ethernet for maintenance
- PMC I/O via PIM for both PMC slots
- Dual SAS ports
|
|
PMC Slot |
Dual PMC I/O access on the front panel |
|
Front panel LEDs |
Blue hot-swap LED, alarm LED, operate LED |
Dimensions
|
Height |
12-RU (14-slot) [21-inch, 533mm] |
|
Width |
17.7-inch, 444mm |
|
Depth |
482mm |
Environment
|
Temperature |
Operating: 0° to 40° Celsius, -5° to 55° Celsius short-term |
|
Humidity |
Five to 85 percent RH noncondensing, five to 90 percent RH short-term |
|
Seismic |
Earthquake Zone 4, per GR63-CORE |
|
Acoustic |
ETSI sound power 72 dB declared (attended limit), per ISO 9296, 23 degrees C inlet temperature |
|
Cooling |
12° C at inlet, ambient temperatures of 25.5° C and above. Dual redundant hotshelf manager (SHM)
EN 300 019-2-1 Class 1.2, EN 300 019-2-2 (except rain and condensation) Class 2.3, EN 300 019-2-3 Class 3.1 (except -5° C cold start) |
|
Input Power |
-40 V DC to -72 V DC |
|
Shelf Manager Carriers |
14-slot cardcage with two shelf manager cards |
Regulatory Compliance
|
Safety and Ergonomics |
cUL: UL60950-1 first edition/CSA C22.2 No. 60950-1-03 CB Report: IEC 60950-1:2001 with all national differences TUV GS: EN60950-1:2000 GOST R and Russian Hygienics Argentina S-Mark |
|
Regulatory Compliance |
Class A limits, FCC CFR47 Part 15, ICES-003, EN55022 (CE), VCCI, BSMI, C-Tick, GOST, MIC |
|
Immunity |
EN55024:1998, EN300 386v1.3.1, EN61000-4- 2,-3,-4,-5,-6, -8, 11 |
|
Warranty |
Standard one-year return to depot |
|
Telecom Environment Certification |
NEBS Level 3-certified |